ME2-CO Electrochemical Carbon Monoxide Sensor
Review: 5 - "A masterpiece of literature" by , written on May 4, 20020
Great

ME2-CO Electrochemical Carbon Monoxide Sensor

Available:In Stock
R$ 75,00

Application:Widely used in commercial especially residential occasions to detect CO gas concentration.
Feature:Low consumption,High precision,High sensitivity,Wide linear range

Production Description:

ME2-CO electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current.

Feature:

  • * Low consumption  
  • * High precision
  • * High sensitivity
  • * Wide linear range
  • * Good anti-interference ability
  • * Excellent repeatability and stability

Application:

Widely used in commercial especially residential occasions to detect CO gas concentration.

Technical Parameters:

Item

Parameter

Detection gas

CO

Measurement Range

0~1000 ppm

Max detecting concentration

2000 ppm

Sensitivity

>0.015 µA/ppm

Resolution ratio

0.5 ppm

Response time(T90)

<50 s

Load resistance(recommended)

(120/200/300) Ω

Repeatability

<3﹪output value

Stability(/year)

<10﹪

Output Linearity

linear

Zero drift(-20℃~40℃)

≤10 ppm

Storage temperature

-20℃~50℃

Storage Humidity

15﹪~90﹪RH

Pressure range

  normal atmosphere ±10%                  

Anticipated using life

7 years

Application:Widely used in commercial especially residential occasions to detect CO gas concentration.
Feature:Low consumption,High precision,High sensitivity,Wide linear range

Production Description:

ME2-CO electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current.

Feature:

  • * Low consumption  
  • * High precision
  • * High sensitivity
  • * Wide linear range
  • * Good anti-interference ability
  • * Excellent repeatability and stability

Application:

Widely used in commercial especially residential occasions to detect CO gas concentration.

Technical Parameters:

Item

Parameter

Detection gas

CO

Measurement Range

0~1000 ppm

Max detecting concentration

2000 ppm

Sensitivity

>0.015 µA/ppm

Resolution ratio

0.5 ppm

Response time(T90)

<50 s

Load resistance(recommended)

(120/200/300) Ω

Repeatability

<3﹪output value

Stability(/year)

<10﹪

Output Linearity

linear

Zero drift(-20℃~40℃)

≤10 ppm

Storage temperature

-20℃~50℃

Storage Humidity

15﹪~90﹪RH

Pressure range

  normal atmosphere ±10%                  

Anticipated using life

7 years