ME2-CO Electrochemical Carbon Monoxide Sensor
- Product SKU: INFME2CO
- Category:Best selling products,Home page,Winsen Sensors
Application:Widely used in commercial especially residential occasions to detect CO gas concentration.
Feature:Low consumption,High precision,High sensitivity,Wide linear range
Production Description:
ME2-CO electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current.
Feature:
- * Low consumption
- * High precision
- * High sensitivity
- * Wide linear range
- * Good anti-interference ability
- * Excellent repeatability and stability
Application:
Widely used in commercial especially residential occasions to detect CO gas concentration.
Technical Parameters:
Item |
Parameter |
Detection gas |
CO |
Measurement Range |
0~1000 ppm |
Max detecting concentration |
2000 ppm |
Sensitivity |
>0.015 µA/ppm |
Resolution ratio |
0.5 ppm |
Response time(T90) |
<50 s |
Load resistance(recommended) |
(120/200/300) Ω |
Repeatability |
<3﹪output value |
Stability(/year) |
<10﹪ |
Output Linearity |
linear |
Zero drift(-20℃~40℃) |
≤10 ppm |
Storage temperature |
-20℃~50℃ |
Storage Humidity |
15﹪~90﹪RH |
Pressure range |
normal atmosphere ±10% |
Anticipated using life |
7 years |
Application:Widely used in commercial especially residential occasions to detect CO gas concentration.
Feature:Low consumption,High precision,High sensitivity,Wide linear range
Production Description:
ME2-CO electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current.
Feature:
- * Low consumption
- * High precision
- * High sensitivity
- * Wide linear range
- * Good anti-interference ability
- * Excellent repeatability and stability
Application:
Widely used in commercial especially residential occasions to detect CO gas concentration.
Technical Parameters:
Item |
Parameter |
Detection gas |
CO |
Measurement Range |
0~1000 ppm |
Max detecting concentration |
2000 ppm |
Sensitivity |
>0.015 µA/ppm |
Resolution ratio |
0.5 ppm |
Response time(T90) |
<50 s |
Load resistance(recommended) |
(120/200/300) Ω |
Repeatability |
<3﹪output value |
Stability(/year) |
<10﹪ |
Output Linearity |
linear |
Zero drift(-20℃~40℃) |
≤10 ppm |
Storage temperature |
-20℃~50℃ |
Storage Humidity |
15﹪~90﹪RH |
Pressure range |
normal atmosphere ±10% |
Anticipated using life |
7 years |