MG-812 Low Power-Consumption CO2 Sensor
Review: 5 - "A masterpiece of literature" by , written on May 4, 20020
Great

MG-812 Low Power-Consumption CO2 Sensor

Available:In Stock
R$ 127,50

Application:CO2 detection in air quality control, ferment process control and green house fields.
Feature:Small sizes, low power-consumption, high sensitivity and good selectivity.

Production Description:
MG-812 is a semiconductor oxide chemical sensor that uses solid electrolyte battery principles to detect CO2.
When the sensor is kept at a certain working temperature and placed in a CO2 atmosphere, an electrode reaction occurs between the positive and negative electrodes of the battery, and the output signal voltage is inversely proportional to the logarithm of the CO2 concentration. A voltage change in the test signal can detect a change in the CO2 concentration.
Feature:

  • Small sizes, low power-consumption, high sensitivity and good selectivity.
  • Less affection by temperature and humidity.
  • Good stability and repeatability.

Application:
CO2 detection in air quality control, ferment process control and green house fields.
Main technical parameters:

Model No.

       MG812

Standard pack

       Metal shell

Target gas

       CO2

Detection range

0~10000ppm CO2

Heater voltage VH

5.0±0.1 V

Heater resistance RH

60.0±5Ω

Heater current IH

85±10mA

Heater consumption PH

420±50mW

Working temp Tao

-20~50℃

Storage temp

-20~70℃

Zero EM F

200-400mV

(in 400ppm CO2)

Output signal  △EM F

≧20mV

EMF (40ppmCO2)- EMF (1000ppmCO2)

Application:CO2 detection in air quality control, ferment process control and green house fields.
Feature:Small sizes, low power-consumption, high sensitivity and good selectivity.

Production Description:
MG-812 is a semiconductor oxide chemical sensor that uses solid electrolyte battery principles to detect CO2.
When the sensor is kept at a certain working temperature and placed in a CO2 atmosphere, an electrode reaction occurs between the positive and negative electrodes of the battery, and the output signal voltage is inversely proportional to the logarithm of the CO2 concentration. A voltage change in the test signal can detect a change in the CO2 concentration.
Feature:

  • Small sizes, low power-consumption, high sensitivity and good selectivity.
  • Less affection by temperature and humidity.
  • Good stability and repeatability.

Application:
CO2 detection in air quality control, ferment process control and green house fields.
Main technical parameters:

Model No.

       MG812

Standard pack

       Metal shell

Target gas

       CO2

Detection range

0~10000ppm CO2

Heater voltage VH

5.0±0.1 V

Heater resistance RH

60.0±5Ω

Heater current IH

85±10mA

Heater consumption PH

420±50mW

Working temp Tao

-20~50℃

Storage temp

-20~70℃

Zero EM F

200-400mV

(in 400ppm CO2)

Output signal  △EM F

≧20mV

EMF (40ppmCO2)- EMF (1000ppmCO2)