MQ-2 Semiconductor Sensor for Flammable Gas
- Product SKU: INFMQ-2
- Category:Best selling products,Home page,Winsen Sensors
Application:It is widely used in domestic gas leakage alarm, industrial flammable gas alarm and portable gas detector.
Feature:It has good sensitivity to propane, smoke &etc in wide range, and has advantages such as long lifespan, low cost and simple drive circuit &etc.
Production Description:
Sensitive material of MQ-2 gas sensor is SnO2, which with lower conductivity in clean air. When the target flammable gas exist, the sensor’s conductivity gets higher along with the gas concentration rising. Users can convert the change of conductivity to correspond output signal of gas concentration through a simple circuit.
MQ-2 gas sensor has high sensitivity to propane and smoke, also can detect the natural gas and other flammable steam well. It is with low cost and suitable for different applications of detecting kinds of flammable gases.
Feature:
It has good sensitivity to propane, smoke &etc in wide range, and has advantages such as long lifespan, low cost and simple drive circuit &etc.
Application:
It is widely used in domestic gas leakage alarm, industrial flammable gas alarm and portable gas detector.
Technical Parameters:
Model |
MQ-2 |
||
Sensor Type |
Semiconductor |
||
Standard Encapsulation |
Bakelite, Metal cap |
||
Target Gas |
Flammable gas, smoke |
||
Detection range |
300~10000ppm(flammable gas) |
||
Standard Circuit Conditions |
Loop Voltage |
Vc |
5.0V±0.1V DC |
Heater Voltage |
VH |
5.0V±0.1V AC or DC |
|
Load Resistance |
RL |
Adjustable |
|
Sensor character under standard test conditions |
Heater Resistance |
RH |
30Ω±3Ω(room temp.) |
Heater consumption |
PH |
≤950mW |
|
Sensitivity |
S |
Rs(in air)/Rs(2000ppm C3H8)≥5 |
|
Output Voltage |
Vs |
2.5V~4.0V(in 2000ppmC3H8) |
|
Concentration Slope |
α |
≤0.6(R3000ppm/R1000ppmC3H8) |
|
Standard test conditions |
Tem. Humidity |
20℃±2℃;55%±5%RH |
|
Standard test circuit |
Vc:5.0V±0.1V; VH:5.0V±0.1V |
||
Preheat time |
Not less than 48 hours |
||
O2content |
21%(not less than 18%) O2 concentration effects initial value, sensitivity and repeatability. |
||
Lifespan |
|
10 years |
Application:It is widely used in domestic gas leakage alarm, industrial flammable gas alarm and portable gas detector.
Feature:It has good sensitivity to propane, smoke &etc in wide range, and has advantages such as long lifespan, low cost and simple drive circuit &etc.
Production Description:
Sensitive material of MQ-2 gas sensor is SnO2, which with lower conductivity in clean air. When the target flammable gas exist, the sensor’s conductivity gets higher along with the gas concentration rising. Users can convert the change of conductivity to correspond output signal of gas concentration through a simple circuit.
MQ-2 gas sensor has high sensitivity to propane and smoke, also can detect the natural gas and other flammable steam well. It is with low cost and suitable for different applications of detecting kinds of flammable gases.
Feature:
It has good sensitivity to propane, smoke &etc in wide range, and has advantages such as long lifespan, low cost and simple drive circuit &etc.
Application:
It is widely used in domestic gas leakage alarm, industrial flammable gas alarm and portable gas detector.
Technical Parameters:
Model |
MQ-2 |
||
Sensor Type |
Semiconductor |
||
Standard Encapsulation |
Bakelite, Metal cap |
||
Target Gas |
Flammable gas, smoke |
||
Detection range |
300~10000ppm(flammable gas) |
||
Standard Circuit Conditions |
Loop Voltage |
Vc |
5.0V±0.1V DC |
Heater Voltage |
VH |
5.0V±0.1V AC or DC |
|
Load Resistance |
RL |
Adjustable |
|
Sensor character under standard test conditions |
Heater Resistance |
RH |
30Ω±3Ω(room temp.) |
Heater consumption |
PH |
≤950mW |
|
Sensitivity |
S |
Rs(in air)/Rs(2000ppm C3H8)≥5 |
|
Output Voltage |
Vs |
2.5V~4.0V(in 2000ppmC3H8) |
|
Concentration Slope |
α |
≤0.6(R3000ppm/R1000ppmC3H8) |
|
Standard test conditions |
Tem. Humidity |
20℃±2℃;55%±5%RH |
|
Standard test circuit |
Vc:5.0V±0.1V; VH:5.0V±0.1V |
||
Preheat time |
Not less than 48 hours |
||
O2content |
21%(not less than 18%) O2 concentration effects initial value, sensitivity and repeatability. |
||
Lifespan |
|
10 years |